Air conditioning control unit

Air conditioning control unit allows to control temperature and humidity. Heating or cooling and humidifier or dehumidifier can be connected to two panel sockets. The unit has an internal auxiliary outputs with two power relays. One relay is for humidity, the other for temperature control. Each relay has NO/NC contacts rated 20A. The combination enables four regimes: heating / cooling and humidify / dehumidify. The unit comply IP54.

Size:   240 x 115 x 130mm
Voltage:   240 ... 240 V AC
Socket output:   10 A each
Auxiliary outputs:   20 A each
Sensor temperature range:   -20°C ... +80°C
Sensor humidity range:   3 ... 99% RH
Measurement temperature precision:   ±0.5°C
Measurement humidity precision:   ±3% RH
Resolution:   0.1°C    0.1% RH